CVE Professor — Güvenlik Açığı Takip & Analiz
›
CVE-2026-89929

YÜKSEK Güvenlik Açığı

YÜKSEK CVSS 8.8 ⚡ EPSS 0.2% NVD

In the Linux kernel, the following vulnerability has been resolved: KVM: nVM: Ensure INVVPID is emulated on the correct physical CPU When emulating INVVPID, KVM executes INVVPID on the physical CPU using vpid02 (instead of the L1 assigned VPID), after doing some validations on the operands. However, it is possible that the physical CPU KVM executes INVVPID on is different from the CPU L2 is running on. For example, in the following scenario: - L2 runs on CPU #1 and exits to L1 (vmx->nested.vmcs02.cpu=1) - L1 migrates to CPU #2 and executes INVVPID - KVM executes INVVPID on CPU #2 - L1 migrates back to CPU #1 and runs L2 (vmx->nested.vmcs02.cpu=1) The TLB entries on CPU #1 are never invalidated, because INVVPID was executed on CPU #2, and vmcs02 never ran on a different pCPU (i.e. vmx_vcpu_load_vmcs() will *not* request KVM_REQ_TLB_FLUSH). Ensure that INVVPID is being executed on the same pCPU that L2 last ran on, and if not, fallback to clearing last_vpid=0 to trigger a full VPID flush on the next nested VM-Enter (as KVM will detect L1 using a different VPID for L2). If L2 ends up running on a different pCPU, KVM will flush the TLB anyway through vmx_vcpu_load_vmcs().

Yayınlanma 16.09.2026
ISO Tarih 2026-09-16
CVSS Sürüm v3.1
Kaynak NVD
CVSS v3.1 Metrikleri
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Attack Vector Local AV:L
Attack Complexity Low AC:L
Privileges Req. Low PR:L
User Interaction None UI:N
Scope Changed S:C
Confidentiality High C:H
Integrity High I:H
Availability High A:H
EPSS — Exploit Olasılık Skoru
0.2%
30 günlük olasılık
Tüm CVElerin 6. yüzdeliğinde — Bu açığın istismar edilme ihtimali çoğu CVEden yüksek.
AI Güvenlik Analizi

━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
CVE-2026-89929
CVSS 8.8/10 · YÜKSEK · 16.09.2026
Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

🎯 AÇIK NEDİR?
Açıklama: In the Linux kernel, the following vulnerability has been resolved:

KVM: nVM: Ensure INVVPID is emulated on the correct physical CPU

When emulating INVVPID, KVM executes INVVPID on the physical CPU using
vpid02 (instead of the L1 assigned VPID), after doing some validations
on the operands. However, it is possible that the physical CPU KVM
executes INVVPID on is different from the CPU L2 is r…

⚡ SALDIRI ZİNCİRİ
Yerel/fiziksel erişim | düşük yetkili hesap | kullanıcı etkileşimi YOK | düşük karmaşıklık.
⚠️ Scope değişiyor — etki diğer sistemlere sıçrayabilir.

🌍 GERÇEK DÜNYA ETKİSİ
Tüm gizli veriler okunabilir/çalınabilir; sistem verileri değiştirilebilir/silinebilir; hizmet tamamen devre dışı bırakılabilir; diğer sistemlere pivot mümkün.

🛡️ ÇÖZÜM VE MİTİGASYON
→ Üretici tarafından yayınlanan yamayı uygula.
→ WAF kuralı ekle, anormal trafik için IDS alert oluştur.

⚠️ ACİLİYET
⚠️ Planlı bakım (2 hafta) — Yüksek seviye.

────────────────────────────────────────
[Kural Tabanlı Analiz] [💡 config.json dosyasına ai_key (Claude: sk-ant-... veya Groq: gsk_...) ekleyerek gerçek AI analizi kullanabilirsiniz]

[⚠️ AI key mevcut ancak istek başarısız — kural tabanlı analiz kullanıldı]

Hedef Keşif Sorguları
CVSS Skoru
8.8 / 10 · CVSS YÜKSEK